{"title":"Fire Notification Devices","description":null,"products":[{"product_id":"system-sensor-p2rled-2-wire-led-horn-strobe-red","title":"System Sensor P2RLED L-Series 24V 2-Wire LED Horn Strobe, Wall-Mount, FIRE, Red","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe System Sensor P2RLED is a standard-size, wall-mounted audible and visible fire-alarm notification appliance from the L-Series LED platform. It combines a selectable-output horn and clear-lens LED strobe in a red, tamper-resistant housing marked “FIRE.”\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for 24V notification appliance circuits, the P2RLED uses LED strobe technology to reduce current draw compared with legacy xenon appliances. Lower power requirements can provide greater flexibility when calculating NAC capacity, voltage drop and power-supply requirements.\u003c\/p\u003e\n\u003cp\u003eSeven field-selectable wall-strobe settings—15, 30, 75, 95, 110, 135 and 185 candela—allow installers to configure the visual output for the intended room and code requirements. Eight horn configurations provide Temporal 3 or continuous operation, standard or 3.1 kHz tones, and high or low volume.\u003c\/p\u003e\n\u003cp\u003eThe supplied universal mounting plate supports a plug-in installation with minimal device intrusion into the electrical box. An onboard shorting spring allows installers to test wiring continuity before attaching the horn strobe, helping protect the device from construction damage and reduce installation-related ground faults.\u003c\/p\u003e\n\u003cp\u003eFront-accessible digital voltage meter test points let technicians check device and end-of-line voltage without removing the appliance from the wall. The P2RLED also supports System Sensor synchronization when connected to a compatible power supply, properly configured fire-alarm control panel or MDL3 synchronization module.\u003c\/p\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eMain Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombined audible horn and visible LED strobe\u003c\/li\u003e\n\u003cli\u003eTwo-wire notification appliance design\u003c\/li\u003e\n\u003cli\u003e24V DC operation\u003c\/li\u003e\n\u003cli\u003eRed housing with clear lens\u003c\/li\u003e\n\u003cli\u003eWall-mount configuration\u003c\/li\u003e\n\u003cli\u003eStandard English “FIRE” marking\u003c\/li\u003e\n\u003cli\u003eLower-current LED strobe technology\u003c\/li\u003e\n\u003cli\u003eSeven field-selectable candela settings\u003c\/li\u003e\n\u003cli\u003e15, 30, 75, 95, 110, 135 and 185 cd options\u003c\/li\u003e\n\u003cli\u003eEight selectable horn configurations\u003c\/li\u003e\n\u003cli\u003eTemporal 3 and non-temporal horn patterns\u003c\/li\u003e\n\u003cli\u003eStandard and 3.1 kHz horn tones\u003c\/li\u003e\n\u003cli\u003eHigh and low volume selections\u003c\/li\u003e\n\u003cli\u003eHorn rated at 88+ dBA at 16V\u003c\/li\u003e\n\u003cli\u003eRotary switches simplify output selection\u003c\/li\u003e\n\u003cli\u003eFront-accessible DVM diagnostic test points\u003c\/li\u003e\n\u003cli\u003ePlug-in appliance and universal mounting plate\u003c\/li\u003e\n\u003cli\u003eOnboard shorting spring supports wiring-continuity testing\u003c\/li\u003e\n\u003cli\u003eTamper-resistant construction\u003c\/li\u003e\n\u003cli\u003eSystem Sensor synchronization support\u003c\/li\u003e\n\u003cli\u003eElectrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-Series devices\u003c\/li\u003e\n\u003cli\u003eIntended for indoor fire-alarm notification applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eCompatibility and Installation Notice\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe P2RLED is a 24V fire-alarm notification appliance and is not a standalone horn or smoke detector. It requires connection to a compatible fire-alarm control panel or listed notification power supply.\u003c\/p\u003e\n\u003cp\u003eElectrical compatibility with earlier System Sensor devices does not automatically confirm that every appliance can be combined on the same NAC. Before installation, verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable NAC voltage and current\u003c\/li\u003e\n\u003cli\u003eRequired synchronization protocol\u003c\/li\u003e\n\u003cli\u003eCircuit polarity and wiring class\u003c\/li\u003e\n\u003cli\u003eVoltage drop at the final appliance\u003c\/li\u003e\n\u003cli\u003eSelected horn and candela settings\u003c\/li\u003e\n\u003cli\u003eFire-alarm panel and power-supply compatibility\u003c\/li\u003e\n\u003cli\u003eApplicable NFPA 72 and local code requirements\u003c\/li\u003e\n\u003cli\u003eApproval by the authority having jurisdiction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProfessional fire-alarm system design and installation are recommended.\u003c\/p\u003e\n\u003ch3\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem Sensor P2RLED horn-strobe appliance\u003c\/li\u003e\n\u003cli\u003eUniversal wall-mounting plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSurface-mount back boxes, trim rings, synchronization modules, wiring and other accessories are sold separately unless explicitly stated otherwise.\u003c\/p\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eRecommended Applications\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial fire-alarm systems\u003c\/li\u003e\n\u003cli\u003eCorporate and professional buildings\u003c\/li\u003e\n\u003cli\u003eSchools and educational facilities\u003c\/li\u003e\n\u003cli\u003eHealthcare properties\u003c\/li\u003e\n\u003cli\u003eHotels and hospitality facilities\u003c\/li\u003e\n\u003cli\u003eRetail stores\u003c\/li\u003e\n\u003cli\u003eMultifamily buildings\u003c\/li\u003e\n\u003cli\u003eWarehouses and industrial properties\u003c\/li\u003e\n\u003cli\u003eGovernment facilities\u003c\/li\u003e\n\u003cli\u003eNew installations and compatible L-Series upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eTechnical Specifications\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP2RLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003eL-Series LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eLED horn strobe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotification type\u003c\/td\u003e\n\u003ctd\u003eAudible and visible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003eTwo-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting orientation\u003c\/td\u003e\n\u003ctd\u003eWall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct size\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing color\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLens color\u003c\/td\u003e\n\u003ctd\u003eClear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing marking\u003c\/td\u003e\n\u003ctd\u003eFIRE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003eRegulated 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating-voltage range\u003c\/td\u003e\n\u003ctd\u003e16–33V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCandela settings\u003c\/td\u003e\n\u003ctd\u003e15, 30, 75, 95, 110, 135 and 185 cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrobe flash rate\u003c\/td\u003e\n\u003ctd\u003e1 flash per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorn configurations\u003c\/td\u003e\n\u003ctd\u003e8 selectable tone\/volume combinations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorn patterns\u003c\/td\u003e\n\u003ctd\u003eTemporal 3 and non-temporal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorn frequencies\u003c\/td\u003e\n\u003ctd\u003eStandard and 3.1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume settings\u003c\/td\u003e\n\u003ctd\u003eHigh and low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorn rating\u003c\/td\u003e\n\u003ctd\u003e88+ dBA at 16V; output varies by setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current range\u003c\/td\u003e\n\u003ctd\u003e35–190 mA RMS depending on horn and candela settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor Sync protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic feature\u003c\/td\u003e\n\u003ctd\u003eFront-accessible DVM voltage test points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible wire size\u003c\/td\u003e\n\u003ctd\u003e12–18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting boxes\u003c\/td\u003e\n\u003ctd\u003e4\" × 4\" × 1½\", single-gang, double-gang, 4\" octagonal or compatible SBBRL surface box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.67\"H × 4.70\"W × 2.07\"D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32°F–120°F (0°C–49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e10–93%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL\/ULC Listed, FM Approved and CSFM Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e783863058851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":54565273862419,"sku":null,"price":86.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/4370\/2035\/files\/SystemSensorP2RLEDfront.png?v=1786646086"}],"url":"https:\/\/customsystemsupply.com\/collections\/fire-notification-devices.oembed","provider":"Custom System Supply","version":"1.0","type":"link"}